Get Expert-Drafted CAD Drawings from Your Realsee Project
Turn your Realsee project into expert-drafted CAD drawings with manual review and quality checks. Ideal for large spaces, project documentation, design reference, and client-ready deliverables.
Preview the Project. Download the CAD Sample.
Explore a Realsee VR project and download a sample Manual CAD deliverable to understand what customers can receive.
Manual CAD sample file
Download the sample Manual CAD deliverables from Google Drive.
Tips: Demo files are provided for reference only. Final deliverables may vary depending on project size, capture quality, and selected service scope.
When Automatic CAD Is Not Enough
Manual CAD extends your CAD delivery options when automatic CAD is limited by project size, capture conditions, or drawing scope.

Covers Projects Beyond Auto CAD Limits
Automatic CAD has clear boundary conditions. For Galois projects, Auto CAD is limited to 1,000 sqm / approx. 10,764 sqft. For Poincaré projects, Auto CAD may not be available when the capture duration exceeds 15 minutes. Manual CAD can support large-space drafting up to 30,000 sqft / approx. 2,787 sqm.

Specialist Drafting with Cross-Review
Manual CAD drawings are prepared by trained specialists and checked through a cross-review process, helping improve drawing accuracy, consistency, and readability.

RCP Deliverable Available
Manual CAD supports RCP — Reflected Ceiling Plan — as a separate deliverable. This drawing type is not available through automatic CAD output.

Optional Drawing Details
Based on your project needs, you can add visible furniture and casework, visible power/data/control points, opening schedules, and room schedules to the Manual CAD Floorplan deliverable.
Manual CAD Deliverables and File Formats
Manual CAD supports Floorplan and RCP drawing deliverables. Optional drawing details can be added to the Floorplan deliverable based on your documentation needs.
Type 1: Floorplan
A manually prepared CAD floorplan based on your Realsee project data. Optional drawing details can be selected for more complete documentation.
Choose extra drawing details for more complete CAD documentation. These options are available for the Floorplan deliverable only.
Visible Furniture & Casework
Visible Power, Data & Controls
Opening Schedules
Room Schedules
Refer to the FAQ below for what each optional detail includes and how it is delivered.
Type 2: Reflected Ceiling Plan
A separate RCP drawing deliverable for projects that require reflected ceiling plan documentation. RCP is delivered as a separate drawing and does not include the Floorplan detail options.
Manual CAD Pricing in Credits: Three Conditions
Pricing is based on project area, selected drawing type, and optional drawing details.
Project Area
A tiered system according to area.
Drawing Type
Two types: Floorplan and Reflected Ceiling Plan.
Optional Details
Four more optionals for floorplan.
Manual CAD Standard Price Table
| Tier | Area (sqft) | Area (sqm approx.) |
Floorplan
From 40 Credits
|
RCP
From 24 Credits
|
Best Value
FP + RCP
From 52 Credits
|
|---|---|---|---|---|---|
| T1 | 1–1,000 | 0–93 | 40 | 24 | 52 |
| T2 | 1,001–2,000 | 93–186 | 128 | 77 | 166 |
| T3 | 2,001–3,000 | 186–279 | 144 | 86 | 187 |
| T4 | 3,001–4,000 | 279–372 | 160 | 96 | 208 |
| T5 | 4,001–5,000 | 372–465 | 180 | 108 | 234 |
| T6 | 5,001–10,000 | 465–929 | 280 | 168 | 364 |
| T7 | 10,001–30,000 | 929–2,787 | 800 | 480 | 1040 |
Metric equivalents are approximate and shown for reference. The Floorplan + RCP Bundle price is optimized to offer a special discounted rate (approx. 20% off the combined regular price) rather than a simple sum of individual tiers.
Optional Drawing Details Pricing
| TIER | AREA (sqft) | AREA (sqm approx.) | Visible Furniture & Casework | Visible Power, Data & Controls | Opening Schedules | Room Schedules |
|---|---|---|---|---|---|---|
| T1 | 1–1,000 | 0–93 | 8 | 8 | 5 | 4 |
| T2 | 1,001–2,000 | 93–186 | 26 | 26 | 10 | 8 |
| T3 | 2,001–3,000 | 186–279 | 29 | 29 | 13 | 12 |
| T4 | 3,001–4,000 | 279–372 | 32 | 32 | 14 | 13 |
| T5 | 4,001–5,000 | 372–465 | 36 | 36 | 17 | 16 |
| T6 | 5,001–10,000 | 465–929 | 56 | 56 | 19 | 18 |
| T7 | 10,001–30,000 | 929–2,787 | 96 | 96 | 22 | 21 |
Metric equivalents are approximate and shown for reference. Optional drawing details are available for the Manual CAD Floorplan deliverable only.
Estimated Manual CAD Delivery Time
Delivery time, which is based on the project area and the number of selected drawing types, is shown for one selected drawing and will DOUBLE if both Floorplan and RCP are selected.
| AREA (sqft) | AREA (sqm approx.) | Delivery Time for 1 Drawing |
|---|---|---|
| 1–3,000 | 0–279 | 3–5 business days |
| 3,001–10,000 | 279–929 | 4–6 business days |
| 10,001–20,000 | 929–1,858 | 6–9 business days |
| 20,001–30,000 | 1,858–2,787 | 7–10 business days |
Metric equivalents are approximate and shown for reference. Delivery tiers are calculated by floor area in sqft.
Request Manual CAD in Four Simple Steps
After completing your capture, open Console, select the project that requires Manual CAD, and go to the Add-ons page.
Select Floorplan, RCP, or Floorplan + RCP, and choose any Optional Drawing Details you need.
Review the required Credits, selected drawing scope, and estimated delivery time before submitting your order.
Once processing is complete, download the Manual CAD files from your project deliverables.
Frequently Asked Questions
Which projects support Manual CAD?
Manual CAD is currently available only for projects captured with Poincaré and Galois devices.
Are Manual CAD deliverables editable?
Yes. Manual CAD deliverables include editable AutoCAD .DWG files plus .DXF files, so your architect or contractor can work with them directly. .PDF files are also included for quick sharing.
How accurate are Manual CAD deliverables?
Manual CAD geometry is produced to LOD 200. Measured accuracy depends on the capture device: ±10 mm with Galois P4 and ±20 mm with Galois M2, both within the LOA 20 band.
Can Manual CAD deliverables be used for permitting or construction?
Manual CAD deliverables provide an accurate scan-derived as-built base. Because the deliverables are not a field survey, we recommend independent field verification before relying on them for construction, permitting, or as-built records.
How long does delivery take?
Standard delivery is tiered by floor area, from 3–5 business days for smaller spaces up to 7–10 business days for the largest. The estimate is per selected drawing type: selecting both Floorplan and RCP doubles the production time shown in the delivery table.
What formats do I get?
You receive .DWG, .DXF, .CTB, and .PDF files. The .DWG file also includes a point-cloud reference layer for verification. If you add schedules, door, window, and room schedule files are also delivered as .XLSX and .CSV files.
What is included in Visible Furniture & Casework?
Adds visible, scan-captured furniture, major appliances, and fixed casework to the Floorplan as scaled footprints at standard sizes, positioned as found in the scan.
Included
| Category | Items |
|---|---|
| Seating | Sofas, chairs, benches |
| Tables | Dining, coffee, side, desks |
| Beds | Single / double / queen / king by size |
| Storage furniture | Cabinets, wardrobes, shelving units, dressers |
| Fixed casework | Built-in cabinetry, kitchen units, countertops, vanities, wardrobes |
| Major appliances | Refrigerator, oven / range, dishwasher, washer / dryer, and other large built-in or freestanding units |
| Displays & heating | Televisions / monitors; radiators as furniture footprint |
How items are drawn
- Scaled footprint / outline only, not modeled in detail.
- Not differentiated by material or finish.
- Placed and oriented per scan.
Not included
- Bespoke / custom pieces are shown as footprint outline only, not detailed.
- Small loose objects on surfaces, signage, and artwork.
- Visible electrical points, which are covered by Visible Power, Data & Controls.
What is included in Visible Power, Data & Controls?
Adds wall- and floor-mounted visible electrical points to the Floorplan as standard 2D symbols. These show the locations of devices visible in the scan, not conduits, circuits, or engineering design.
Included
| Group | Items |
|---|---|
| Power | Sockets / outlets with number of connections noted, floor boxes |
| Data & comms | Data / network outlets, telephone outlets, TV outlets |
| Controls | Light switches, thermostats, control panels for security / AV / access |
| Panels | Distribution boards, low-voltage / data enclosures |
| Wall-mounted devices | Smoke / heat detectors, extract fans, doorbell / intercom |
How items are drawn
- Standard 2D symbols, placed per scan.
- Sockets are annotated with number of connections; wall devices include mounting height where relevant.
- Modeled only where clearly visible and unobstructed in the scan.
Not included
- Conduits, wiring runs, circuits, or load calculations.
- Concealed / behind-wall services.
- Ceiling-mounted lights, diffusers, detectors, and fans, which are part of the base Reflected Ceiling Plan.
What is included in Door & Window Schedules?
Adds door and window schedules with ID, size, type, and swing information, cross-referenced to the door / window tags on the plan so every opening on the drawing has a matching schedule entry.
Delivered as
Embedded on the Floorplan schedule sheet, plus standalone .PDF, .XLSX, and .CSV files for both the door schedule and window schedule. Schedules cross-reference plan tags such as D01 and W01.
What is included in Room Schedules?
Adds a room schedule listing each room’s name, number, area, perimeter, ceiling height (CH), and floor finish. Room names follow the Realsee standard room vocabulary.
Delivered as
Embedded on the Floorplan schedule sheet, plus standalone .PDF, .XLSX, and .CSV files. The schedule includes per-floor subtotals and a project grand total.
Does this include MEP / electrical engineering?
No. The Visible Power, Data & Controls add-on shows the locations of visible devices, such as sockets, switches, and panels. It does not include conduits, circuits, wiring, engineering design, MEP engineering, or concealed services.
What’s the difference between RCP and the Visible Power, Data & Controls add-on?
RCP covers ceiling-mounted items such as lights, diffusers, ceiling detectors, and extract fans as part of its base scope. The Visible Power, Data & Controls add-on is for the Floorplan deliverable only and covers visible wall- and floor-mounted electrical, data, and control points.
Should I choose Imperial or Metric?
Choose the system your downstream users work in. Imperial defaults to NCS (AIA) layer naming for North America, while Metric defaults to ISO 13567 for Europe and international projects. The choice also sets dimension format and sheet sizes. Learn more
How is pricing calculated?
Pricing is based on the floor-area tier. Each drawing type has a base price per tier; add-ons are priced per tier on top of the Floorplan; and RCP can be bundled with a Floorplan at a discount.
Why are room names provided in English only?
Manual CAD room names currently support English only. Room names are drawn from the Realsee standard room vocabulary to keep deliverables consistent. Where a space’s function cannot be determined from the scan, it is labeled “Room”.
Are elevations or sections available?
Not yet. Elevations and sections are coming soon. The current release covers Floorplan and Reflected Ceiling Plan deliverables.