1. Overview
Manual CAD Files — As-Built CAD (Measured Existing Conditions)
Professionally hand-drafted 2D CAD documenting your building's measured existing conditions, derived from point-cloud / 3D-tour scan data. Drawings are produced to LOD 200 geometry with a layer structure mapped to both AIA NCS V7 (North America) and ISO 13567 (Europe / International), delivered as editable AutoCAD files (.dwg / .dxf) plus PDF — ready for your team to take straight into design or documentation.
Who it's for
Architects, contractors, surveyors, designers, and other building professionals who need an accurate, editable as-built base of a space as it stands today — without a manual measure-up.
At a glance
|
What it is
|
As-built 2D CAD of existing conditions, drawn from your scan
|
|
Drawing types
|
Floor Plan, Reflected Ceiling Plan (RCP)
|
|
Geometry
|
LOD 200
|
|
Measured accuracy
|
±10 mm (Galois P4) / ±20 mm (Galois M2) — see Standards & Accuracy
|
|
Layer standard
|
AIA NCS V7 (Imperial) / ISO 13567 (Metric)
|
|
Formats
|
.dwg · .dxf · .pdf · .ctb
|
|
Delivery
|
Tiered by area & number of drawings
|
2. What You Receive
Every order is delivered as a complete, editable file set:
|
File
|
Purpose
|
|
.dwg
|
Editable AutoCAD drawing (primary working file).
Includes a dedicated point-cloud reference layer — an orthographic view of the scan aligned to the drawing
|
|
.dxf
|
Interchange format exported from the .dwg, for non-AutoCAD tools
|
|
.pdf
|
Plotted, ready-to-share output of each drawing
|
|
.ctb
|
Plot-style table for consistent printing
|
1. Each drawing type you select (Floor Plan, RCP) is delivered as its own set of the above.
2. See a real example under Sample Files.
2. See a real example under Sample Files.
3. See the FAQs and Glossaries of Dimension
3. Drawing Types
3.1 Floor Plan
Included
-
Walls, interior and exterior, with thickness
-
Doors (with swing) and windows (with swing and type)
-
Room boundaries, names, numbers, areas, and per-room ceiling height (CH)
-
Stairs (up / down direction, treads) and fixed structure (columns, shear walls)
-
Finished Floor Level (FFL), shaft openings, sloped floors (fall direction), skylights, curtain walls
-
Beams / trusses as dashed overhead linework
-
Floor-finish changes (boundaries between different finishes)
Not included
-
Add-ons: furniture & casework, visible power/data/controls, door & window schedules, room schedule
-
Coming soon: elevations, sections
-
Out of scope: roof plans, MEP engineering & concealed services, structural / load calculations
Technical specs
-
Geometry to LOD 200; measured accuracy ±10 mm (P4) / ±20 mm (M2)
-
Includes a point-cloud reference layer (orthographic, aligned to the drawing) within the .dwg
-
Formats: .dwg / .dxf / .pdf / .ctb
3.2 Reflected Ceiling Plan (RCP)
A reflected ceiling plan shows the ceiling of each space, projected as viewed from above.
Included
-
Ceiling outlines, height changes and steps
-
Ceiling openings — light cutouts, access panels, skylights
-
Visible ceiling light fixtures (downlights, linear, pendant)
-
HVAC air terminals / diffusers
-
Ceiling-mounted smoke / heat detectors and extract fans
Not included
-
Lighting circuits and control wiring
-
Electrical engineering, concealed services, equipment selection or load calculations
Technical specs
-
Reflected ceiling plan (ceiling elements projected as viewed from above)
-
Geometry to LOD 200; measured accuracy ±10 mm (P4) / ±20 mm (M2)
-
Includes a point-cloud reference layer (orthographic, aligned to the drawing) within the .dwg
-
Formats: .dwg / .dxf / .pdf / .ctb
3.3 Exterior Elevation
Orthographic exterior views of your building — outlines, door & window elevations, FFL / roof lines, and material boundaries, and ordered per view — North, South, East, or West — each named for the compass direction its facade faces.
All wall planes visible in the same projection, including stepped or recessed sections, belong to that view. Everything listed below is part of the base drawing; Exterior Elevation has no separate add-ons.
Included
-
Building outline and exterior wall lines
-
Doors and windows in elevation, tagged consistently with the Floor Plan
-
Finished Floor Levels (FFL) and roof lines
-
Material change boundaries on the facade
-
Elevation dimensions and level annotations
Not included
-
Interior elevations, sections
-
Facades without exterior scan coverage (e.g. shared walls of attached buildings)
-
Site and landscape context beyond the building line
Technical specs
-
Four principal views (N / S / E / W); additional views for courtyards or wings can be quoted separately
-
Geometry to LOD 200; measured accuracy ±10 mm (P4) / ±20 mm (M2)
-
Layers per AIA NCS V7 / ISO 13567
-
Includes a point-cloud reference layer (orthographic, aligned to the drawing) within the .dwg
-
Formats: .dwg / .dxf / .pdf / .ctb
3.4 Floor Plan Add-ons
Visible Furniture & Casework
Adds visible, scan-captured furniture, major appliances, and fixed casework to the Floor Plan as scaled footprints at standard sizes, positioned as found in the scan.
Included
|
Category
|
Items
|
|
Seating
|
Sofas, chairs, benches
|
|
Tables
|
Dining, coffee, side, desks
|
|
Beds
|
Single / double / queen / king (by size)
|
|
Storage furniture
|
Cabinets, wardrobes, shelving units, dressers
|
|
Fixed casework
|
Built-in cabinetry, kitchen units, countertops, vanities, wardrobes
|
|
Major appliances
|
Refrigerator, oven / range, dishwasher, washer / dryer, and other large built-in or freestanding units
|
|
Displays & heating
|
Televisions / monitors; radiators (as furniture footprint)
|
How items are drawn
-
Scaled footprint / outline only — not modeled in detail
-
Not differentiated by material or finish
-
Placed and oriented per scan
Not included
-
Bespoke / custom pieces — shown as footprint outline only, not detailed
-
Small loose objects on surfaces, signage, and artwork
-
Visible electrical points (see Visible Power, Data & Controls)
Visible Power, Data & Controls
Adds wall- and floor-mounted visible electrical points to the Floor Plan as standard 2D symbols — the locations of devices visible in the scan, not conduits, circuits, or engineering design.
Included
|
Group
|
Items
|
|
Power
|
Sockets / outlets (with number of connections noted), floor boxes
|
|
Data & comms
|
Data / network outlets, telephone outlets, TV outlets
|
|
Controls
|
Light switches, thermostats, control panels (security / AV / access)
|
|
Panels
|
Distribution boards, low-voltage / data enclosures
|
|
Wall-mounted devices
|
Smoke / heat detectors, extract fans, doorbell / intercom
|
How items are drawn
-
Standard 2D symbols, placed per scan
-
Sockets annotated with number of connections; wall devices with mounting height where relevant
-
Modeled only where clearly visible and unobstructed in the scan
Not included
-
Conduits, wiring runs, circuits, or load calculations
-
Concealed / behind-wall services
-
Ceiling-mounted lights, diffusers, detectors and fans — these are part of the base Reflected Ceiling Plan
Door & Window Schedules
Adds door and window schedules — ID, size, type, swing — cross-referenced to the door / window tags on the plan, so every opening on the drawing has a matching schedule entry.
Delivered as: embedded on the Floor Plan's schedule sheet, plus standalone PDF + .xlsx + .csv files (one each for the door and window schedules) for further use. Schedules cross-reference the plan tags (D01, W01…).
Room Schedule
Adds a room schedule listing, per room: name, number, area, perimeter, ceiling height (CH), and floor finish.
Room names follow the Realsee standard room vocabulary
Delivered as: embedded on the Floor Plan's schedule sheet, plus a standalone PDF + .xlsx + .csv file. Includes per-floor subtotals and a project grand total.
4. Accuracy & Standards
Geometry — LOD 200. Drawings are produced to Level of Development 200: generalized elements with accurate size, shape, location, and orientation, suitable for design reference and documentation. Both capture devices below meet LOD 200.
Measured accuracy — by capture device.
Accuracy depends on the device used to capture the space. Under the USIBD Level of Accuracy (LOA) framework — which defines each level as a tolerance range at 95% confidence — the devices sit as follows:
|
Capture device
|
Rated accuracy
|
USIBD LOA band
|
|
Galois P4
|
±10 mm
|
within LOA30 (5–15 mm)
|
|
Galois M2
|
±20 mm
|
within LOA20 (15–50 mm)
|
These figures sit on the measured side of the USIBD framework — the accuracy of the captured data.
The represented side (the drawing itself) is controlled separately: drawn geometry is held to within ±15 mm of the point cloud, and the point-cloud reference layer in every .dwg lets you check the drawing against the scan yourself. Verifying accuracy against the building itself requires on-site reference measurements, which only a field team can take — if your project calls for formal verification, spot-check key dimensions on site against the drawing.
"Measured accuracy" is independent of display precision — an Imperial drawing can display to 1/4" while being measured to the tolerance above.
Layer standards — NCS V7 / ISO 13567. Layer naming follows the system that matches your region:
-
Imperial → AIA NCS V7 (U.S. National CAD Standard), the norm for North American reviewers and permitting.
-
Metric → ISO 13567, the European / international convention.
The two are mapped to each other, so the same content is organized consistently whichever system you choose.
When you order Manual CAD Files from Realsee, you're not getting a one-off drawing drawn to someone's personal habits. Every deliverable follows a documented standard that is mapped to nine established international and industry standards — the same standards your architects, contractors, and reviewers already work with. This page explains what those standards are, what each one governs, and — importantly — what "standards-compatible" does and doesn't mean.
The nine standards we map to
Different parts of a CAD drawing answer to different standards. Here's what governs what:
| Standard | What it governs in your drawings |
| AIA NCS V7 (U.S. National CAD Standard) | Layer naming, sheet numbering, sheet sizes, title blocks, and overall drawing-set organization — for North America |
| ISO 13567 | Layer naming for Europe and international projects |
| ISO 12006-2 | The building-element classification behind the layer structure |
| ISO 128 | Drafting conventions — line weights, line types, and views |
| AIA CAD Layer Guidelines / AIA E202 | Layer-organization principles and the Level-of-Development framework |
| USIBD LOA v3.1 (U.S. Institute of Building Documentation) | Measured-accuracy levels — the tolerance band your drawing is held to |
| BIMForum LOD 2025 | Level of Development — the geometric detail of the elements |
| Architectural Graphic Standards | Dimensioning conventions, abbreviations, and how doors, windows, stairs, and casework are drawn |
| NKBA | Standard representation of kitchen and bath fixtures |
In addition, the layer classification is cross-mapped to Uniclass 2015 (UK), OmniClass (US), and CI/SfB (Northern Europe), so the same drawing can be understood across regional classification systems.
5. Units & Delivery
Your Unit selection drives more than number format — it cascades through dimensioning, sheet sizes, and layer organization.
Choose the system your downstream users and reviewers work in, and the rest follows automatically.
What the unit changes
|
|
Metric (mm)
|
Imperial (ft-in)
|
|
AutoCAD units
|
Decimal
|
Architectural
|
|
Dimension format
|
2700
|
8'-10"
|
|
Display precision
|
Whole mm
|
1" / 1/4" / 1/8" / 1/16"
|
|
Area unit
|
m²
|
sf
|
|
Sheet-size series
|
ISO A (A0–A4)
|
ANSI / ARCH
|
|
Layer-naming system
|
ISO 13567-mapped
|
AIA NCS V7
|
|
Units note on sheet
|
"All dimensions in mm…"
|
"…in feet and inches…"
|
Which to choose
-
North America → Imperial + NCS V7.
-
Europe / Australia / International → Metric + ISO 13567.
-
When in doubt, match the system your architect, contractor, or authority works in — that's what the deliverable should align to.
Delivery time
Standard delivery is tiered by floor area. The times below are per drawing;
When you order more than one drawing type, multiply by the number selected (e.g. Floor Plan + RCP = the per-drawing time × 2).
|
Area
|
Per-drawing delivery (business days)
|
|
0 – 1,000 sqft
|
3 – 5
|
|
1,001 – 2,000 sqft
|
3 – 5
|
|
2,001 – 3,000 sqft
|
3 – 5
|
|
3,001 – 4,000 sqft
|
4 – 6
|
|
4,001 – 5,000 sqft
|
4 – 6
|
|
5,001 – 10,000 sqft
|
4 – 6
|
|
10,001 – 20,000 sqft
|
6 – 9
|
|
20,001 – 30,000 sqft
|
7 – 10
|
6. How It Works & Pricing
How to order
-
Start from a captured 3D tour / scan of your space.
-
Select your drawing types (Floor Plan, RCP) and any Floor Plan add-ons.
-
Choose your unit (Imperial / Metric) ,display precision and other configs.
-
Place the order — your editable CAD set is delivered within the stated turnaround.
How pricing works
Pricing is tied to floor area. Each drawing type has a base price per area tier; Add-ons are priced per tier on top of the Floor Plan.
RCP can be ordered on its own or bundled with a Floor Plan at a discounted bundle price.
Prices are shown in Credits.
Floor Plan — price by area tier (Credits)
|
Tier
|
Area
|
Standard FP
|
+ Visible Furniture & Casework
|
+ Visible Power, Data & Controls
|
+ Door & Window Schedules
|
+ Room Schedule
|
|
T1
|
1 – 1,000 sqft
|
40
|
8
|
8
|
5
|
4
|
|
T2
|
1,001 – 2,000 sqft
|
128
|
26
|
26
|
10
|
8
|
|
T3
|
2,001 – 3,000 sqft
|
144
|
29
|
29
|
13
|
12
|
|
T4
|
3,001 – 4,000 sqft
|
160
|
32
|
32
|
14
|
13
|
|
T5
|
4,001 – 5,000 sqft
|
180
|
36
|
36
|
17
|
16
|
|
T6
|
5,001 – 10,000 sqft
|
280
|
56
|
56
|
19
|
18
|
|
T7
|
10,001 – 30,000 sqft
|
800
|
96
|
96
|
22
|
21
|
Add-on columns are the additional Credits added to the Standard FP price for that tier.
Reflected Ceiling Plan — price by area tier (Credits)
|
Tier
|
Area
|
RCP (standalone)
|
Floor Plan + RCP bundle
|
|
T1
|
1 – 1,000 sqft
|
24
|
52
|
|
T2
|
1,001 – 2,000 sqft
|
77
|
166
|
|
T3
|
2,001 – 3,000 sqft
|
86
|
187
|
|
T4
|
3,001 – 4,000 sqft
|
96
|
208
|
|
T5
|
4,001 – 5,000 sqft
|
108
|
234
|
|
T6
|
5,001 – 10,000 sqft
|
168
|
364
|
|
T7
|
10,001 – 30,000 sqft
|
480
|
1,040
|
The Floor Plan + RCP bundle is priced below ordering the two separately. Live pricing for your specific project is shown at checkout.
Exterior Elevation
|
Tier
|
Area
|
Exterior Elevation
per view
|
Exterior Elevation
4-view bundle (15% off)
|
|
T1
|
1 – 1,000 sqft
|
30
|
102
|
|
T2
|
1,001 – 2,000 sqft
|
100
|
340
|
|
T3
|
2,001 – 3,000 sqft
|
110
|
374
|
|
T4
|
3,001 – 4,000 sqft
|
120
|
408
|
|
T5
|
4,001 – 5,000 sqft
|
140
|
476
|
|
T6
|
5,001 – 10,000 sqft
|
180
|
612
|
|
T7
|
10,001 – 30,000 sqft
|
480
|
1632
|
7. Scope & Limitations
-
Scan-derived, not a field survey — Drawings are produced from point-cloud / 3D-tour scan data to the measured accuracy of the capture device, rather than a traditional field survey. Independent field verification is recommended before use for construction, permitting, or as-built records.
-
Obstructions & inferred geometry — Where areas are obstructed, inaccessible, or not captured (behind fixed objects, above ceilings, inside service rooms), geometry may be inferred. Inferred areas are noted in the drawing's General Notes so you can distinguish measured from inferred work.
-
Point-cloud reference — Each .dwg includes a point-cloud reference layer (orthographic, aligned to the drawing) for checking against the scan. It is a layer within the drawing, not a separate point-cloud dataset.
-
Out of scope — MEP engineering design, concealed services, and structural / load calculations are not included.
-
Coming soon — Interior elevations and sections are not yet available and will be released later.