FAQs
How accurate are the drawings?
Geometry is produced to LOD 200. Measured accuracy depends on the capture device: ±10 mm with Galois P4, ±20 mm with Galois M2 — both within the LOA 20 band.
Can I use these for permitting or construction?
They are an accurate as-built base, but because they are scan-derived rather than a field survey, we recommend independent field verification before relying on them for construction, permitting, or as-built records.
How long does delivery take?
Standard delivery is tiered by floor area, from 3–5 business days for smaller spaces up to 7–10 for the largest. Times are per drawing — ordering more than one drawing type multiplies accordingly (e.g. Floor Plan + RCP = ×2).
What formats do I get? .dwg, .dxf, .pdf, and a .ctb plot-style table.
The .dwg also includes a point-cloud reference layer for verification.
If you add schedules (door / window / room), they're also delivered as .xlsx and .csv files.
Does this include MEP / electrical engineering?
No. The Visible Power, Data & Controls add-on shows the locations of visible devices (sockets, switches, panels, etc.) — not conduits, circuits, wiring, or engineering design. MEP engineering and concealed services are out of scope.
What's the difference between the RCP and the Visible Power & Data Controls add-on?
The RCP covers ceiling-mounted items (lights, diffusers, ceiling detectors, extract fans) as part of its base. RCP has no add-ons.
The Floor Plan add-on covers wall- and floor-mounted electrical points.
Should I choose Imperial or Metric?
Pick the system your downstream users work in. Imperial defaults to NCS V7 layer naming (North America); Metric defaults to ISO 13567 (Europe / International). The choice also sets dimension format and sheet sizes.
How is pricing calculated?
By floor-area tier. Each drawing type has a base price per tier; add-ons are priced per tier on top of the Floor Plan; RCP can be bundled with a Floor Plan at a discount.
Why are room names in English / not what I labeled them?
Room names are drawn from the Realsee standard room vocabulary to keep deliverables consistent. Where a space's function can't be determined from the scan, it is labeled "Room".
Dimension & level abbreviations
Abbreviations follow the U.S. National CAD Standard (NCS) convention.
Some regions use alternative terms — e.g. FFE (Finished Floor Elevation) for FFL, or "Ground Floor / First Floor" numbering.
|
Abbreviation
|
Term
|
Meaning
|
|
FFL
|
Finished Floor Level / Line
(*also FFE — Finished Floor Elevation)
|
Datum — top of the finished floor
|
|
EGL
|
Exterior Ground Line
|
Datum — exterior finished grade
|
|
EL.
|
Level / Elevation prefix
|
Precedes an elevation value, e.g. "EL. +2700"
|
|
AFF
|
Above Finished Floor
|
Modifier — measured up from the floor's FFL
|
|
AFG
|
Above Finished Grade
|
Modifier — measured up from exterior grade (EGL)
|
|
CH
|
Ceiling Height
|
Clear height — FFL to underside of ceiling
|
|
FFH
|
Floor-to-Floor Height
|
FFL to FFL of the floor above (includes slab thickness)
|
|
Head Ht
|
Head Height
|
FFL to head (top) of a door / window opening
|
|
Sill Ht
|
Sill Height
|
FFL to window sill
|
|
OW / OH
|
Opening Width / Height
|
Width / height of a door or window opening
|
|
ST
|
Slab Thickness
|
Thickness of the floor slab
|
|
Plenum
|
Ceiling Plenum
|
Void above the ceiling
|
|
HCD
|
Head-to-Ceiling Distance
|
Realsee-defined: head of a window / door to the underside of the ceiling
|
Standards & quality abbreviations
|
Abbreviation
|
Term
|
Meaning
|
|
LOD
|
Level of Development
|
Geometric detail of elements (drawings are LOD 200)
|
|
LOA
|
Level of Accuracy
|
Measured tolerance band (drawings are LOA 20; ±10 mm P4 / ±20 mm M2)
|
|
RCP
|
Reflected Ceiling Plan
|
Ceiling plan projected as viewed from above
|
|
FP
|
Floor Plan
|
Horizontal plan cut at approx. 1.2 m
|
|
NCS
|
U.S. National CAD Standard
|
Layer-naming standard (V7) used for Imperial orders
|
|
ISO 13567
|
ISO layer standard
|
Layer-naming standard used for Metric orders
|
|
CTB
|
Color-based plot-style table
|
Controls plotted output
|
Window type codes (Window Schedule)
|
Code
|
Type
|
|
FX
|
Fixed
|
|
CS
|
Casement
|
|
SH
|
Sliding (horizontal)
|
|
SV
|
Sliding (vertical)
|
|
AW
|
Awning
|
|
FC
|
Floor-to-Ceiling
|
|
BAY
|
Bay window
|
|
LV
|
Louver
|
Standard room vocabulary
Room names come from the two tables below and are chosen by each room's actual function.
Where a space's function cannot be determined from the scan, it is labeled "Room".
Residential
|
Category
|
ROOM NAME
|
Notes
|
|
Primary Living Spaces
|
Living Room
|
Primary living space; do not use Lounge / Sitting Room
|
|
Family Room
|
More casual than the living room; secondary living space
|
|
|
Dining Room
|
Standalone dining room
|
|
|
Kitchen
|
|
|
|
Kitchen / Dining
|
Open-plan combined kitchen-dining
|
|
|
Breakfast Nook
|
Small dining area off the kitchen
|
|
|
Pantry
|
Storage room off the kitchen
|
|
|
Bedrooms
|
Master Bedroom
|
Primary owner's bedroom
|
|
Primary Bedroom
|
Gender-neutral alternative to Master
|
|
|
Bedroom 2
|
Numbered (Bedroom 2 / 3 / 4…)
|
|
|
Bedroom 3
|
|
|
|
Guest Bedroom
|
Designated guest room
|
|
|
Nursery
|
|
|
|
Walk-in Closet
|
Walk-in wardrobe off the bedroom
|
|
|
Dressing Room
|
Standalone dressing room
|
|
|
Bathrooms (by scenario)
|
Bathroom
|
Full bath: shower or tub + toilet + basin (residential default)
|
|
Powder Room
|
Half bath: toilet + basin only (no shower)
|
|
|
Ensuite
|
Bathroom directly connected to a bedroom
|
|
|
Half Bath
|
Equivalent to Powder Room
|
|
|
Full Bath
|
Equivalent to Bathroom; common in real-estate listings
|
|
|
Work / Study
|
Study
|
Mainly for reading / study
|
|
Home Office
|
Work-oriented
|
|
|
Library
|
Emphasis on book storage
|
|
|
Den
|
Small multi-purpose space (US usage)
|
|
|
Entry / Circulation
|
Entry
|
Small entrance space
|
|
Foyer
|
Larger, formal entrance
|
|
|
Vestibule
|
Small transitional space before the entry
|
|
|
Hallway
|
|
|
|
Corridor
|
For longer corridors
|
|
|
Stairwell
|
Stair space; numbered with S prefix (e.g. S101)
|
|
|
Landing
|
Rest platform between stair flights
|
|
|
Utility / Service
|
Laundry
|
|
|
Mudroom
|
US; stores coats / boots near the entry
|
|
|
Storage
|
|
|
|
Closet
|
US; do not use Cupboard
|
|
|
Linen Closet
|
Small closet for linens / towels
|
|
|
Coat Closet
|
Small entry closet for coats
|
|
|
Utility
|
Space housing plumbing / electrical services
|
|
|
Mechanical
|
Houses HVAC, water heater, electrical panel
|
|
|
Boiler Room
|
|
|
|
Server Room
|
Rare in homes; more common in commercial
|
|
|
Outdoor / Semi-outdoor
|
Balcony
|
Outdoor, covered
|
|
Terrace
|
Outdoor, uncovered / roof terrace
|
|
|
Patio
|
Ground-level paved courtyard
|
|
|
Porch
|
Covered entry transition (common in US)
|
|
|
Sunroom
|
Glass-enclosed semi-outdoor space
|
|
|
Garden
|
Soft landscape
|
|
|
Garage
|
Indoor parking
|
|
|
Carport
|
Covered, wall-less parking
|
|
|
Basement / Attic
|
Basement
|
Numbered with B prefix (B101)
|
|
Cellar
|
Storage-oriented basement
|
|
|
Wine Cellar
|
|
|
|
Attic
|
Usable space under the roof
|
|
|
Crawl Space
|
Low, non-habitable underfloor space
|
|
|
Recreation
|
Media Room
|
With TV / projector
|
|
Game Room
|
|
|
|
Gym
|
Home fitness space
|
|
|
Bar
|
|
|
|
Lounge
|
Semi-formal leisure space (not used for the living room)
|
Office & Commercial
|
Category
|
ROOM_NAME
|
Notes
|
|
Office Spaces
|
Office
|
General
|
|
Open Office
|
|
|
|
Private Office
|
Single-occupant
|
|
|
Executive Office
|
Large, private
|
|
|
Partitioned workspace
|
||
|
Workstation
|
Single workstation
|
|
|
Meeting / Collaboration
|
Meeting Room
|
General
|
|
Conference Room
|
Larger, formal
|
|
|
Boardroom
|
High-spec meeting room
|
|
|
Huddle Room
|
2–4 person quick meetings
|
|
|
Phone Booth
|
Single-person call booth
|
|
|
Training Room
|
|
|
|
Classroom
|
|
|
|
Reception / Public
|
Reception
|
Near the main entrance
|
|
Lobby
|
Larger public entrance area
|
|
|
Waiting Area
|
|
|
|
Atrium
|
Full-height public space
|
|
|
Break / Dining
|
Break Room
|
Staff break + refreshments
|
|
Pantry
|
Equivalent to Break Room; pick one and use consistently
|
|
|
Cafeteria
|
Staff canteen
|
|
|
Kitchenette
|
Small space: microwave + fridge + sink only
|
|
|
Restrooms
|
Restroom
|
Standard term for commercial buildings (replaces residential Bathroom)
|
|
Mens Restroom
|
|
|
|
Womens Restroom
|
|
|
|
Accessible Restroom
|
|
|
|
Family Restroom
|
Common in US
|
|
|
Equipment / Service
|
IT Room
|
Houses servers / network equipment
|
|
Server Room
|
Larger IT space
|
|
|
Telecom
|
Telecom equipment room
|
|
|
Electrical Room
|
Main electrical room
|
|
|
Janitor
|
Janitor's closet
|
|
|
Mailroom
|
|
|
|
Print Room
|
|
|
|
Copy Room
|
|
|
|
Supply Room
|
|
|
|
Records Room
|
|
|
|
Retail / Service
|
Sales Floor
|
Main retail sales space
|
|
Showroom
|
|
|
|
Fitting Room
|
Common in retail
|
|
|
Stockroom
|
Retail back-of-house
|
|
|
Cashier
|
|